19 research outputs found

    Open and endovascular repair of juxtarenal abdominal aortic aneurysms: a systematic review

    Get PDF
    This systematic review focuses on the 30-day mortality associated with open surgery and fenestrated endografts for short-necked

    3D-Printed Models Applied in Medical Research Studies

    Get PDF
    The aim of this chapter is to show experiments in cardiology and fetal medicine, two specialties of medicine, through the development of three dimensional (3D) physical models produced on additive manufacturing (AM) technologies, also known as 3D printing, from files acquired on noninvasive-imaging technologies (NITs) as 3D ultrasound (3DUS), magnetic resonance imaging (MRI), computed tomography (CT), and micro-computed tomography (micro-CT). The presentation of eight different experiments demonstrates that the combination of AM technologies and files obtained from NITs may improve our understanding of medical anatomical characteristics for medical research, simulation procedures, and educational purposes

    Texto Coletivo: Possibilidades e Limites no Processo de Ensino- Aprendizagem a Distância

    Get PDF
    O presente artigo advém de um trabalho coletivo que visa abordar a aprendizagem colaborativa/cooperativa e suas possibilidades e limites na utilização das tecnologias. Omesmo foi desenvolvido coletivamente na disciplina Seminário Avançado: Oficinas Virtuais de Aprendizagem. Utilizamos a ferramenta ETC para escrita deste. Serão discutidas as possibilidades de construção do processo de ensino-aprendizagem a distância no desenvolvimento de um trabalho coletivo, envolvendo cooperação, colaboração, interação e interatividade. Entre as questões que se levantam pretende-seentender essa linguagem no âmbito das práticas mediadas por tecnologias; como motivar o diálogo entre os participantes para despertar nesses sujeitos o papel de criadores e como a escolarização mediada por tecnologias pode fazer a diferença na vida profissional dos sujeitos e na sua formação

    C02 intravascu/ar injector: in vivo ear/y feasibility study of the device and image quality assessment

    No full text
    INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viávelINTRODUCTION: During endovascular procedures, several risks related to iodinated contrast media are taken, such as Contrast Induced Nephropathy, since these are fundamental to obtain radiological vascular images under fluoroscopy. Intravascular medical grade CO2 injection is a widely accepted and relatively safer alternative to iodinated contrast, but its handling and manual delivery system could as well bring risks to patients, such as room air injection. To address these problems, we developed a prototype for a micro processed intravascular medicinal CO2 injector, dedicated to help obtain angiographic images. OBJECTIVES: To perform the in vivo Early Feasibility Clinical Studies of the prototype. METHODS: Perform a left renal artery angioplasty of 10 pigs, divided in 2 groups: Group 1 (n=5) injection of iodinated contrast and Group 2 (n=5) injection of CO2 with the prototype. Clinical and laboratorial data were measured pre, peri and post-operatively, by pre-operative and 48h post- operative creatinine tests and 3 peri-operative serial arterial blood gas analysis. Animais were kept under clinical observation for 48h after procedures. RESUL TS: Angioplasty procedures had 100% technical success in both groups, without the need of extra imaging with iodinated contrast in Group 2. There were no technical failures with the prototype. There were no identifiable clinical or radiological signs of room air intravascular injections. Ali laboratorial measurements were under normal value ranges. Angiography images obtained in Group 2 were subjectively considered inferior to images from Group 1. DISCUSSION: The inferior image quality in Group 2 could be attributed to the employed fluoroscopy equipment, since its software is not up to date to current equipment, which includes a dedicated CO2 angiography preset. Nevertheless, ali procedures in Group 2 were successful, and images in this group were therefore considered satisfactory. Handling of the prototype proved to be user friendly, since ali injection parameters are performed through a touch screen panel, much superior from previous authors experience with manual saline submerged syringe filling before intravascular injection. CONCLUSIONS: The intravascular CO2 injector prototype worked properly during the tests and the obtained images allowed successful procedures without unexpected complications, in consonance with previous positive in vitro results. Therefore, the study results suggest the positive early technical feasibility of the devic

    Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea

    No full text
    O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha), reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA) no tratamento de um aneurisma de artéria poplítea

    The Arch and Beyond: Bare Stents in the Ascending Aorta

    No full text
    corecore